Plasma and Fusion Research

Volume 21, 1201032 (2026)

Rapid Communications


Local Moment Vector Analysis for Quantification of Spatial Pattern Distortion in Tomography Measurement
Taiki KOBAYASHI1,2), Akihide FUJISAWA1,2,3), Yoshihiko NAGASHIMA1,2), Chanho MOON1,2), Kotaro YAMASAKI4), Daiki NISHIMURA3), Sigeru INAGAKI5), Akihiro SHIMIZU1,3), Tokihiko TOKUZAWA1,3), Takeshi IDO1,2,3)
1)
Research Institute for Applied Mechanics, Kyushu University, Kasuga 816-8580, Japan
2)
Research Center for Plasma Turbulence, Kyushu University, Kasuga 816-8580, Japan
3)
National Institute for Fusion Science, National Institute of Natural Sciences, Toki 509-5292, Japan
4)
Graduate School of Advanced Science and Engineering, Hiroshima University, Higashihiroshima 739-8527, Japan
5)
Institute of Advanced Energy, Kyoto University, Uji 611-0011, Japan
(Received 29 January 2026 / Accepted 12 March 2026 / Published 18 June 2026)

Abstract

A tomography system in the PANTA device found fluctuation pattern distortion during a cycle of the solitary wave oscillations, and global moment vector analysis quantified the degree of the distortion successfully. The method can be refined by help of Fourier-Rectangular Function Expansion to analyze local property of the distortion. This article present the method, called the local moment vector analysis, which can evaluate the local distortion of fluctuation patterns, with the results obtained by applying the local method to the solitary wave oscillations.


Keywords

linear plasma, tomography, pattern analysis

DOI: 10.1585/pfr.21.1201032


References

  • [1] A. Fujisawa et al., Plasma Phys. Control. Fusion 58, 025005 (2016).
  • [2] T.-K. Kobayashi et al., Sci. Rep. 14, 12175 (2024).
  • [3] K. Yamasaki et al., J. Appl. Phys. 126, 043304 (2019).
  • [4] D. Nishimura et al., J. Appl. Phys. 129, 093301 (2021).