Plasma and Fusion Research

Volume 20, 1201027 (2025)

Rapid Communications


Measurement of Ion Temperature during the Intermittent Negative Spike in Floating Potential
Yuto YAMADA1), Atsushi OKAMOTO1), Takaaki FUJITA1), Yuichi KAWACHI1), Minami SUGIMOTO1), Koki SATO1), Muneo KOIKE1), Kota TAKEDA1), Kazuhiro TORII1), Shinji YOSHIMURA2)
1)
Nagoya University, Nagoya 464-8603, Japan
2)
National Institute for Fusion Science, Toki 509-5292, Japan
(Received 31 January 2025 / Accepted 2 March 2025 / Published 13 May 2025)

Abstract

The ion temperature in an ECR plasma is determined from the ratio of wavelength-integrated spectra obtained using a spectrometer with sufficient time resolution. The ion temperature during the intermittent negative spikes in floating potential is extracted using the conditional averaging method. For the first time, we have successfully observed a decrease in ion temperature during intermittent events.


Keywords

ion temperature, high-temperature bubble, electron cyclotron resonance plasma, Doppler spectroscopy, conditional average

DOI: 10.1585/pfr.20.1201027


References

  • [1] K. Terasaka et al., Phys. Plasmas 25, 052113 (2018).
  • [2] A. Okamoto et al., Jpn. J. Appl. Phys. 62, SL1022 (2023).
  • [3] A. Okamoto et al., Plasma Fusion Res. 14, 1201165 (2019).
  • [4] D. Hamada et al., Plasma Fusion Res. 13, 3401044 (2018).
  • [5] S. Kado and T. Shikama, J. Plasma Fusion Res. 79, 841 (2003).