Plasma and Fusion Research
Volume 11, 2405108 (2016)
Regular Articles
- Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193, Japan
Abstract
High-power and long-pulse arc discharges of 150kW for 100 s have been achieved for the first time by suppressing oxygen-induced-arcing which was one of the critical issues on JT-60SA negative ion source. Toward the realization of such arc discharge, the suppression of recycling of oxygen from the arc chamber wall was found to be a key issue in the large-size arc-driven negative ion source. Because the experimental results showed that this oxygen was derived from release of water due to high temperature chamber wall of heated by an arc discharge, the baking of the arc chamber was tried to reduce water adsorbing to the chamber before the long-pulse discharge. After the baking at 80 °C for 8 hours, since the oxygen level was reduced to half of that before baking, the available pulse duration became twice longer. By combining this baking and long-pulse conditioning shots, the stable long-pulse arc discharge has been obtained. This result contributes to the improvement of availability of the large-size negative ion sources which require long-conditioning time.
Keywords
ion source, arcing, JT-60SA, N-NBI
Full Text
References
- [1] S. Ishida et al., Nucl. Fusion 51, 094018 (2011).
- [2] Y. Kamada et al., Nucl. Fusion 51, 073011 (2011).
- [3] M. Hanada et al., J. Plasma Fusion Res. Ser. 9, 208 (2010).
- [4] A. Kojima et al., Nucl. Fusion 55, 063006 (2015).
- [5] M. Yoshida et al., Fusion Eng. Des. 96-97, 616 (2015).
- [6] Y. Okumura et al., Rev. Sci. Instrum. 67, 1018 (1996).
- [7] Y. Ikeda et al., Fusion Eng. Des. 82, 791 (2007).
- [8] M. Kuriyama et al., Fusion Eng. Des. 26, 445 (1995).
- [9] F. Schwirzke, J. Nucl. Mater. 128-129, 609 (1984).
- [10] T. Inoue et al., Fusion Eng. Des. 55, 291 (2001).