Abstract
In this study, using a scintillator-based lost fast-ion probe, we have measured fast-ion losses in the Large Helical Device, in which the losses were caused by externally applied static magnetic perturbations (MPs) having small amplitudes. Energy and pitch-angle resolved measurements reveal that the effects of MPs on fast-ion losses occur in both high and low pitch-angle regions. A Lorentz orbit-following calculation indicates that static MPs can change the orbits of fast ions, which can enhance the transport/loss of fast ions.
Keywords
fast ion, Large Helical Device, lost-fast ion probe, static magnetic perturbation
Full Text
References
- [1] A. Loarte et al., Nucl. Fusion 47, S203 (2007).
- [2] H. Zohm, Plasma Phys. Control. Fusion 38, 105 (1996).
- [3] P. Lang et al., Nucl. Fusion 53, 043004 (2013).
- [4] T. Hender et al., Nucl. Fusion 32, 2091 (1992).
- [5] T. Evans et al., Phys. Rev. Lett. 92, 235003 (2004).
- [6] Y. Liang et al., Phys. Rev. Lett. 98, 265004 (2007).
- [7] W. Suttrop et al., Phys. Rev. Lett. 106, 225004 (2011).
- [8] K. Toi et al., Nucl. Fusion 54, 033001 (2014).
- [9] K. Ogawa et al., Plasma Fusion Res. 3, S1082 (2008).
- [10] K. Ogawa et al., J. Plasma Fusion Res. 8, 655 (2009).
- [11] K. Toi et al., Plasma Phys. Control. Fusion 53, 024008 (2011).
- [12] I. Yamada et al., Fusion Sci. Tech. 58, 345 (2010).
- [13] T. Tokuzawa et al., Fusion Sci. Tech. 58, 352 (2010).
- [14] S. Zweben et al., Nucl. Fusion 30, 1551 (1990).
- [15] K. Ogawa et al., Plasma Fusion Res. 7, 2402014 (2012).
This paper may be cited as follows:
Kunihiro OGAWA, Mitsutaka ISOBE, Kazuo TOI, Akihiro SHIMIZU, Masaki OSAKABE and LHD Experiment Group, Plasma Fusion Res. 9, 3402097 (2014).